1 / 1
Hantek
Authorized brand
Bandwidth(-3dB) 50MHz
HT8000 high voltage isolated probe adopts the differential input mode. It's mainly used in the place that needs high voltage isolation measurement. This high voltage isolated probe has two options of attenuation, 1/50 and 1/500. The difference module measurement range is 130V (DC+peakAC) and 1300V (DC+peakAC). It has over range warning function, indicates by red LED light. It has small and nice appearance, firm and durable structure, good stability, reliability and accuracy.
Model Number HT8050
Bandwidth(-3dB) 50MHz
Rise time 7ns
Accuracy ±2%
Attenuation Ratio 1/50,1/500
Imput Impedance Single-ended to ground:4MΩ
Between two imput ends:8MΩ
Imput Capacitance Single-ended to ground:7pF
Between two imput ends:3.5pF
Maximum Difference Measurement Voltage 1/50:130V(DC+peakAC)
1/500:1300V(DC+peakAC)
Maximum Common Mode Input Voltage 1000Vrms,CATII
600Vrms,CATIII
Noise 1/50:≤1.5mVrms
1/500:≤1mVrms
Linearity ±1%
Delay Time 20ns±1ns
CMRR DC:≥80dB
100KHz:≥60dB
1MHz:≥50dB
Over Range Warning
Voltage Threshold 1/50:140V±4V(DC+peakAC)
1/500:1400V±40V(DC+peakAC)
Power Adapter
Output Power DC9V,1000mA
Power Adapter
Input Power AC100-240V,50-60Hz